e
ea
eb
ec
ed
ee
ef
eg
eh
ei
ej
ek
el
em
en
eo
ep
eq
er
es
et
eu
ev
ew
ex
ey
Перевод: excitation
[существительное] возбуждение [существительное]
Тезаурус:
- If the rotor is initially at the phase A equilibrium position when the excitation is changed to phase B the rotor experiences a positive torque which moves the rotor to the phase B equilibrium.
- Apart from simple evasive and defensive reactions, in which they play a dominant role, reflex arcs seem mainly to be involved in perfecting movements that are initiated by central mechanisms or in helping to maintain the nervous system in a state of adequate excitation.
- Asoma Instruments has introduced a bench top ED-XRF analyser, the model 200T, that uses an X-ray tube for sample excitation rather than radio-isotopes.
- The characteristics are approximated by the sinusoidal functions: The effect of exciting a pair of phases together is shown in Fig. 3.6(b) where the peak static torque is improved by a factor of 1-;4 over one-phase-on excitation - For phases A and B excited by positive current the total torque is: and similarly for other phase combinations.
- As an example consider a hybrid stepping motor in which the peak static torque produced by each phase is proportional to the phase current and the phase torques vary sinusoidally with rotor position: For conventional operation the windings are excited by positive and negative rated current, giving a step length of r/2p for each excitation change.
- After 24h at room temperature to allow diffusion along axonal membranes, hindbrains were dissected from the embryos, flat-mounted in fixation buffer and viewed both under green excitation on a fluorescence microscope (Zeiss, set 15) and a confocal microscope (BioRad) using the 514 nm laser line.
- The detailed electronic circuit is shown in Fig. 14 and consists of three basic sections, a power driver for the excitation coil and two identical sense amplifiers.
- Faris claims that unlike the Josephson junction, the quiteron is insensitive to stray magnetic fields, and returns to equilibrium automatically when the external excitation is turned off.
- The magnet flux in section X has to flow radially outwards and the excitation of A therefore results in most of the magnet flux flowing in poles 3 and 7.
- The effect of changing the excitation from stack A to stack B is to produce alignment of the stator and rotor teeth in stack B. This new alignment is made possible by a movement of the rotor in the clockwise direction; the motor moves one step as a result of the excitation change.
- The spectrometer has dedicated tube secondary target excitation for enhanced reliability.
- Where freedom of expression is at stake, the same ethical standards are relevant, particularly where the works in question offer sexual excitation through scenes of rape or torture.
- If the excitation of A is removed and B is excited with positive current then alignment of the stator and rotor teeth has to occur under poles 4,8 of section X and poles 2,6 of section Y. The rotor moves one step clockwise to attain the correct position.
|